E-T-A High PerformanceCircuit breakerApplication Fields
58彩票This type ofCircuit breakerVery suitable for overcurrent and short circuit protection in vehicle and aviation technology, and automatic in measurement, control, and regulation systemsCircuit breakerAlternative options.
ETACircuit breaker/High performanceCircuit breakerApplication Fields
58彩票It is an ideal choice for line protection and main switch of motor vehicles, electric vehicles, ships, airplanes, etc., as well as for load independent remote shutdown of gasoline and diesel vehicles, railway vehicles, and ships.
technology
58彩票583 series high-performance Circuit breaker A thermal trip or thermal magnetic trip with high breaking capacity Circuit breaker And the battery Circuit breaker Also based on the principle of thermal magnetic release. Circuit breaker The hot part provides delay protection when overloaded. Under high overload and short-circuit current conditions, magnetic components will shut down the faulty circuit within a few milliseconds.
We can provide customer specific designs upon request, such as SG, AP, or CBM types. All in this category Circuit breaker All provide true electrical isolation.
Kewei Technology has been focusing on imported brands for 12 years, with a professional FAE team capable offreeProvide you with a range of productsUser guide, please contact the technical personnel for details.
58彩票Li Gong: 18576410868
threeExtreme, high-performance aviation circuit breaker with free tripping and manual operationPush pull switch(MType conformity CBE EN 60934).Neck ThreadPanel installation, temperature compensation, optional auxiliary contacts
Typical applications |
Used for auxiliary low-voltage supply on various land, sea, and air transportation vehiclesElectrical system.includeTransport planes, fighter jets, helicopters, unmanned aerial vehicle training planes, and similar fields.
Ordering Information | |
Model sequence | |
five hundred and eighty-three | Unipolar with temperature compensation |
install | Screw panel installation |
Nut standard | M12×1 |
Nuts and washers | wave washer 12/15, standard configuration |
Wiring terminals | Nut with metric thread K14(M4) |
tripcurve | |
Wiring screws | Philips screwsM4×6Standard waveform washerB4,Standard configuration |
Auxiliary contact point | Without auxiliary contacts |
baffle | No barrier |
Button | Black with white logo(e.g.two point five) |
Rated current value | 1…35A |
583-SG901 | Order Example 583-SG975-15A Select the rated current value from the following table |
Circuit breakerRated currentvalueandcorrespondingTypical internal resistance value | |||
Rated current(A) | Voltage drop/extremely(mV) | Rated current(A) | Voltage drop/extremely(mV) |
1 | seven hundred and fifty | seven point five | two hundred and thirty |
2 | five hundred and twenty | ten | one hundred and ninety |
2.5 | four hundred | 15 | one hundred and ninety |
3 | three hundred and sixty | 20 | two hundred |
4 | three hundred and fifty | 25 | one hundred and seventy |
5 | two hundred and sixty | thirty | one hundred and sixty |
technical parameter | |
Rated voltage | 3 AC 200 V (400 Hz);DC 28 V |
1...30 A | |
Auxiliary circuit | 0 .5 A, DC 28 V |
Typical lifespan | Mechanical operation20,000second Rated currentIN (≤25 A)lower10,000second Rated currentIN (≤30 A)lower4,000second |
ambient temperature | -55...+125°C (-67...+257°F)≤15 A -55...+90°C (-67...+194°F) > 15 A |
Insulation coordination | Rated impulse voltageclass of pollution 1.5 kV3 |
Dielectric strength (IEC 60664 and60664A) work area | Test voltage AC 1,500 V AC 1,500 V AC 1,500 V |
insulation resistance | >100 MΩ(DC 500 V) |
Circuit breaking capacityIN | ≤4 A 1,000 A 5 A 2,000 A 7.5...25 A 2,500 A 30 A 1,500 A 1...25 A 6,000 A 30 A 4,000 A |
Protection level (IEC 60529) | Operation areaIP40 Contact areaIP00 |
Vibration(sine) | 10 g (57-2000 Hz),±0.76 mm (5-57 Hz), PressVG 95210, sheet 19, IEC 60068-2-6, test Fc, ISO 7137 |
Vibration | 16.4 g rms, 0.2 g2 Hz±1.5 dB, PressVG 95210, sheet 29, IEC 60068-2-6, test Fc, ISO 7137 |
acceleration | 17 g, to ISO 2669 |
50 g (11 ms),to VG 95210, sheet 28, IEC 60068-2-27, test Ea, ISO 7137 | |
Salt spray | 96 hours at 5 %Salt spray;48 hours at 20 %Salt spray; PressVG 95210, sheet 2, IEC 60068-2-11, test Ka, ISO 7137 |
humidity | two hundred and forty hour95 % RH,PressVG 95210, sheet 7andIEC 60068-2-3, test C/ISO 7137 |
blast | PressVG 95210, sheet 10, MIL-STD-202, meth. 109 |
Altitude | ≤25,000 maltitude |
heavyamount | About with auxiliary contacts67gWithout auxiliary contacts, approximately63g |
Kewei Technology has been focusing on imported brands for 12 years, with a professional FAE team capable offreeProvide you with a range of productsUser guide, please contact the technical personnel for details.
Li Gong: 18576410868
ETA High Performance断路器Example of ordering model:
583-G411-K1M1-A1S0TN-1A | 583-SG975-1A |
583-G411-K1M1-A1S0TN-2A | 583-SG975-2A |
583-G411-K1M1-A1S0TN-3A | 583-SG975-3A |
583-G411-K1M1-A1S0TN-5A | 583-SG975-5A |
583-G411-K1M1-A1S0TN-7.5A | 583-SG975-7.5A |
583-G411-K1M1-A1S0TN-10A | 583-SG975-10A |
583-G411-K1M1-A1S0TN-15A | 583-SG975-15A |
583-G411-K1M1-A1S0TN-20A | 583-SG975-20A |
583-G411-K1M1-A1S0TN-25A | 583-SG975-25A |
583-G411-K1M1-A1S0TN-30A | 583-SG975-30A |
Kewei Technology has been focusing on imported brands for 12 years, with a professional FAE team capable offreeProvide you with a range of productsUser guide, please contact the technical personnel for details.
Li Gong: 18576410868
If your high-performance circuit breaker requires military standards orairworthiness certificate Requirement, please confirm with the technical personnel in advance:
Certification code | Standard number | Voltage range | Current range |
Bw | VG 95345 | AC115V/200V,400Hz DC28V | 1A-25A 1A-25A |
Bw | LN29887 | AC115V/200V,400Hz | 5A-25A |
Dep of Navy | AS14154 | AC115V/200V,400Hz | 1A-20A |
QPL | VG 95345 | AC115V/200V,400Hz DC28V | 1A-25A 1A-25A |
QPL Sweden | MS 14154 | AC115V/200V,400Hz DC28V | 1A-25A 1A-25A |
QPL UK | LN29887 | AC115V/200V,400Hz | 5A-25A |
Airbus | EN2996-004 | AC115V/200V,400Hz | 1A-25A |
Airbus | EN2996-005 | AC115V/200V,400Hz | 1A-25A |