5G Base Station DC Monitoring Solution Base Station DC Energy Measurement Module AMC16_ Base Station
58彩票 Overview of 5G Base Station Electrical Monitoring Cloud Platform
The smart power consumption cloud platform for base stations installs AC/DC intelligent monitoring devices, wireless acquisition devices, and system management platforms on 5G macro stations and indoor distribution stations to complete power off operations during non business hours at night, reduce energy consumption, lower operating costs, and enhance real-time monitoring and protection of communication equipment power supply line status; The system backend sorts, summarizes, and analyzes the historical electrical performance data of stored power supply lines, identifies the cause of faults, provides solutions and suggestions, reduces the occurrence rate of similar faults in the future, and improves the operation and control capabilities of power supply lines.
Application places of 5G base station electrical monitoring cloud platform
Communication base station operation and maintenance
58彩票 Architecture of the Three 5G Base Station Electrical Monitoring Cloud Platform System
58彩票 Four product selection and typical configuration schemes
58彩票 A newly built base station communication monitoring site
58彩票 Product selection:
Equipment Overview:
The DTSD1352 xSyD series rail type multi circuit power meter is mainly used for measuring the full electrical parameters of multiple three-phase circuits. It can simultaneously connect the current input of x three-phase circuits and y single-phase circuits. It can directly or indirectly measure parameters such as voltage, current, power, power factor, phase angle, imbalance, harmonics, etc.
The specific functions are as follows:
Measurement of full electrical parameters for x three-phase and y single-phase circuits, with external current transformers;
58彩票 Monitor the voltage/current, zero sequence current, and frequency of each phase;
Monitor the power of each phase and total power (active, reactive, apparent);
58彩票 Monitor the power factor of each phase and the total power factor;
Monitor voltage/current phase angle and voltage/current imbalance;
● Monitor the total harmonic and 2-31st harmonic of voltage and current;
58彩票 Record of extreme values of voltage, current, and power for the current month and the previous month;
58彩票 Current, power demand, and real-time current and real-time power demand;
200 event records, recording the action status of DIDO;
● Support alarm outputs such as overvoltage, overcurrent, phase failure, and DI linkage;
● Rate setting for 4 time zones and 14 time periods;
Four quadrant electricity, 12-month compound rate electricity statistics;
58彩票 31 day four quadrant and compound rate energy freeze, forward and reverse energy metering;
Two passive switch inputs, two switch outputs, RS485 communication; Two active switch inputs are used to identify the connection between the oil engine and the mains power.
58彩票 Configuration plan:
58彩票 Installation Example:
58彩票 DC monitoring site of a newly built base station
Product selection:
Equipment Overview:
The AMC16-DETT base station DC energy metering module is mainly designed for base stations with shared needs and switch power supplies without user specific energy metering functions
Designed. The instrument can measure the direct current of six circuits, with a built-in power supply for the Hall sensor. At the same time, it can achieve zero drift calibration through the upper computer software. It has functions such as telemetry, remote signaling, remote adjustment, real-time power measurement, abnormal power supply quality alarm, information storage and processing, and information exchange. The DC energy metering module can measure the DC electricity consumption of three operators, provide detailed data basis for energy-saving improvement of base stations, and provide reliable sub metering solutions for DC distribution equipment.
58彩票 The module has an industrial standard RS485 communication interface and adopts the YD/T1363.3-2014 protocol, which complies with the relevant technical requirements of Q/ZTT2205-2017 "Technical Requirements for Base Station DC Energy Metering Modules" of China Tower Corporation.
58彩票 The specific functions are as follows:
Monitoring equipment system time, total voltage, total output current, total power, total electrical energy, branch voltage, branch current, branch power, and branch electrical energy; LED indicator light display; RS485 communication
Measurement: Starting current: At rated voltage, when the load current value of the measurement module does not exceed 1% of the current, the module starts with a creep current. When there is no current in the current circuit of the measurement module and the voltage applied to the voltage circuit is 85% to 125% of the rated value, the module calculator should not have more than one digital change;
58彩票 ● Alarm: DC voltage output low alarm, DC voltage output high alarm, power outage alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm, memory failure alarm, AC input power outage alarm;
58彩票 ● Timing: Supports broadcasting timing and can remotely calibrate the metering module through RS485 communication interface;
Storage: It has the function of storing historical energy data and historical alarm information, with a memory of 2MB.
Configuration plan:
Installation Example:
标签:5G基站直流监测方案 基站直流电能计量模块AMC16-DETT
铁塔基站能耗监控解决方案Acrel Cloud-6000基站电气监控云平台 一5G基站电气监控云平台概述基站智慧用电云平台通过对5G宏站和室分站点加装交/直流智能监控设备、无线采集设备以及系统管理平台,完成夜间无业务时段的下电操作,减少电能消耗,降...... 2021-03-25 16:25:49
路灯安全用电云平台 助力实现智慧路灯建设 一政策背景随着物联网、下一代互联网、云计算等新一代信息技术的广泛应用,智慧城市已成为必然趋势。近年来,智慧城市新政频出,我国多个城市掀起了智慧城市建设高潮。出台了一系列政...... 2021-03-18 10:29:10
餐饮业油烟监测方案 助力碳达峰碳中和实现 一政策背景今年两会“碳达峰、碳中和”稳居能源领域的C位话题,今年的工作报告,不仅将做好碳达峰、碳中和工作列入2021年重点任务,更要求各行各业制定好2030年前碳排放达峰行动方案,...... 2021-03-18 10:01:48
能耗管理云平台提高企业能耗利用 一背景我国作为“世界工厂”,产业链日渐完善,国产制造加工能力与日俱增,同时碳排放量加速攀升。但我国油气资源相对匮乏,发展低碳经济,重塑能源体系具有重要安全意义。近年来,我国积...... 2021-03-18 09:50:43
I searched the internet to remind you:
1、本信息由搜了网用户发布,搜了网不介入任何交易过程,请自行甄别其真实性及合法性;
2、跟进信息之前,请仔细核验对方资质,所有预付定金或付款至个人账户的行为,均存在诈骗风险,请提高警惕!